For normal operation, you must maintain the operation mode timetable.
To maintain the timetable:
- From the R/3 main menu, select Tools ® CCMS ® Configuration ® OP mode timetable
- Select Normal operation (24 hr), and Display.
- To assign other times to the operation mode, select Normal operation (24 hr) and Maintain.
- Double-click to select the desired start time and the end time.
- Select Assign to assign these times to the operation mode.
- Enter the name of the operation mode to be active for the time period that you defined.
- Save the changes.
- Finally, save the table.
Alternatively, use transaction code SM63 .
The timetable for the 24hr cycle is displayed.
You can only select productive operation modes.
You must always define a full 24-hour cycle, that is the operation modes must be set up for 24-hour system operation. If the timetable is not defined:
- the start configuration according to the profile will remain active
- no unattended automatic operation mode switch is possible
- the Job Scheduling Monitor will not function properly
- when a job is created or released with start date/time, it will not be possible to check whether background processes are available at the start time
- jobs that are scheduled to start when the operation mode is switched are not started.